Federal Pacific SB24N5F FT2032 - Buck Boost Transformer - 240x480 Pri - 24/48 Sec - 5 kVA - 60Hz - 1 Phase - NEMA 3R Encapsulated

Federal Pacific SB24N5F FT2032 - Buck Boost Transformer - 240x480 Pri - 24/48 Sec - 5 kVA - 60Hz - 1 Phase - NEMA 3R Encapsulated




Federal Pacific SB24N5F Transformers 1
Federal Pacific SB24N5F Transformers 1 Federal Pacific SB24N5F Transformers 2 Federal Pacific SB24N5F Transformers 3 Federal Pacific SB24N5F Transformers 4 Federal Pacific SB24N5F Transformers 5
List price: $942.37
You save: $355.09



Your price: $587.28









Product description


The Type FB Insulating and Buck-Boost Transformer has four separate windings, two windings in the primary and two windings in the secondary. The unit is designed for use as an isolating transformer or as an auto-transformer. As an autotransformer the unit can be connected to Buck (decrease) or Boost (increase) a supply voltage. When connected in either the Buck or Boost mode, the unit is no longer an isolating transformer but is an autotransformer. Autotransformers are more economical and physically smaller than equivalent two-winging transformers designed to carry the same load. They will perform the same function as two-winding transformers with the exception of isolating two circuits. Since autotransformers may transmit line disturbances directly, they may be prohibited in some areas by local building codes. Before applying them, care should be taken to assure they are acceptable according to local code.



Product features


  • Four-Winding Design - Allows for eight different wiring methods to provide a multitude of voltage and KVA outputs.
  • Nema 3 Design - Encapsulated design lets you install it where you need it whether that be indoors or outdoors.
  • Size - The compact design of a Buck-Boost Transformer compared to that of an Isolation Transformer allows for installation in smaller places. Saving you space and installation time.
  • Isolation - When used for its name plated configuration, this transformer can be used to provide isolation for your circuit.
  • Limitless uses - Buck-Boost transformers have no limitation on the type of load that can be operated from its output.
  • Quieter - Due to its size compared to a comparably rated Isolation transformer, Buck-Boost transformers will be quieter while handling the same load.


Related products




Boost Voltage (Increase) - SINGLE PHASE
Input Volts Output Volts kVA Amps Connection Diagram
200 220 45.8 208 1 - view »
208 229 47.7 208 1 - view »
220 242 50.4 208 1 - view »
230 276 28.8 104 2 - view »
240 264 55 208 1 - view »
380 418 43.5 104 4 - view »
416 458 47.7 104 4 - view »
430 473 49.3 104 4 - view »
435 457 95.2 208 3 - view »
436 480 50 104 4 - view »
440 462 96.3 208 3 - view »
440 484 50.4 104 4 - view »
450 473 98.4 208 3 - view »
456 479 99.8 208 3 - view »
460 483 101 208 3 - view »
480 504 105 208 3 - view »
Buck Voltage (Reduce) - SINGLE PHASE
Input Volts Output Volts kVA Amps Connection Diagram
220 200 45.8 229 1 - view »
229 208 47.7 229 1 - view »
242 220 50.4 229 1 - view »
276 230 28.8 125 2 - view »
264 240 55 229 1 - view »
418 380 43.5 115 4 - view »
458 416 47.7 115 4 - view »
473 430 49.3 115 4 - view »
457 435 95.2 219 3 - view »
480 436 50 115 4 - view »
462 440 96.3 219 3 - view »
484 440 50.4 115 4 - view »
473 450 98.4 219 3 - view »
479 456 99.8 219 3 - view »
483 460 101 219 3 - view »
504 480 105 219 3 - view »


Boost Voltage (Increase) - THREE PHASE
Input Volts Output Volts kVA Amps QTY rqd Connection Diagram
173 208 37.5 104 2 5 - view »
200 240 43.3 104 2 5 - view »
208 250 45 104 2 5 - view »
362 380 144 208 2 6 - view »
380 418 75.4 104 2 7 - view »
400 440 79.4 104 2 7 - view »
419 440 166 208 2 8 - view »
436 480 86.5 104 2 7 - view »
457 480 181 208 2 8 - view »
480 528 95.3 104 2 7 - view »
480 504 182 208 2 8 - view »
346Y200 416Y240 75 104 3 9 - view »
379Y219 456Y263 82.2 104 3 9 - view »
400Y231 480Y277 86.6 104 3 9 - view »
416Y240 499Y288 90 104 3 9 - view »
Buck Voltage (Reduce) - THREE PHASE
Input Volts Output Volts kVA Amps QTY rqd Connection Diagram
208 173 37.5 125 2 5 - view »
240 200 43.3 125 2 5 - view »
250 208 45 125 2 5 - view »
380 362 144 229 2 6 - view »
418 380 75.4 115 2 7 - view »
440 400 79.4 115 2 7 - view »
440 419 166 229 2 8 - view »
480 436 86.5 115 2 7 - view »
480 457 181 229 2 8 - view »
528 480 95.3 115 2 7 - view »
504 480 182 219 2 8 - view »
416Y240 346Y200 75 125 3 9 - view »
456Y263 379Y219 82.2 125 3 9 - view »
480Y277 400Y231 86.6 125 3 9 - view »
499Y288 416Y240 90 125 3 9 - view »
NOTE: Y configured units must have Y supply for proper operation.



Shipping information


Shipping type Days Price
Ground 1 - 7 $117.10




Product information


Model:
TEMCo product ID
Brand Federal Pacific
Specifications:
Transformer subcategory Buck Boost
Electrical Specifications:
Phase Single
Frequency (Hz) 60
kVA 5
K rating 1
Primary configuration Two Winding
Secondary configuration Two Winding
Reverse connectable Yes
Winding material Copper
Electrostatically shielded No
Connection type Wire Leads
Mechanical Specifications:
Temperature rise (deg C) 115
Insulation system (deg C) 180
Enclosure rating NEMA 3R
Enclosure material Steel
Construction style Enclosed - Encapsulated Core & Coil
Mounting type Wall
Cooling Air/Dry
Other Information:
UL listed Yes
CSA approved Yes
Agency approvals ANSI C57.12, NEMA ST-20, TP1, EPACT 2005 (TP-1 & TSL-2)
Warranty 12 Years
Input voltage Output voltage
240x480 24/48
Weight & Dimensions:
Weight 110.00 lbs. (49.89 kg)
LxWxH 10.63 x 10.19 x 15.00 in.
(27.00 x 25.88 x 38.10 cm)
Shipping weight 21.00 lbs. (9.52 kg)