Federal Pacific SB24N2F FT2030 - Buck Boost Transformer - 240x480 Pri - 24/48 Sec - 2 kVA - 60Hz - 1 Phase - NEMA 3R Encapsulated

Federal Pacific SB24N2F FT2030 - Buck Boost Transformer - 240x480 Pri - 24/48 Sec - 2 kVA - 60Hz - 1 Phase - NEMA 3R Encapsulated




Federal Pacific SB24N2F Transformers 1
Federal Pacific SB24N2F Transformers 1 Federal Pacific SB24N2F Transformers 2 Federal Pacific SB24N2F Transformers 3 Federal Pacific SB24N2F Transformers 4 Federal Pacific SB24N2F Transformers 5
List price: $479.73
You save: $214.06



Your price: $265.67









Product description


The Type FB Insulating and Buck-Boost Transformer has four separate windings, two windings in the primary and two windings in the secondary. The unit is designed for use as an isolating transformer or as an auto-transformer. As an autotransformer the unit can be connected to Buck (decrease) or Boost (increase) a supply voltage. When connected in either the Buck or Boost mode, the unit is no longer an isolating transformer but is an autotransformer. Autotransformers are more economical and physically smaller than equivalent two-winging transformers designed to carry the same load. They will perform the same function as two-winding transformers with the exception of isolating two circuits. Since autotransformers may transmit line disturbances directly, they may be prohibited in some areas by local building codes. Before applying them, care should be taken to assure they are acceptable according to local code.



Product features


  • Four-Winding Design - Allows for eight different wiring methods to provide a multitude of voltage and KVA outputs.
  • Nema 3 Design - Encapsulated design lets you install it where you need it whether that be indoors or outdoors.
  • Size - The compact design of a Buck-Boost Transformer compared to that of an Isolation Transformer allows for installation in smaller places. Saving you space and installation time.
  • Isolation - When used for its name plated configuration, this transformer can be used to provide isolation for your circuit.
  • Limitless uses - Buck-Boost transformers have no limitation on the type of load that can be operated from its output.
  • Quieter - Due to its size compared to a comparably rated Isolation transformer, Buck-Boost transformers will be quieter while handling the same load.


Related products




Boost Voltage (Increase) - SINGLE PHASE
Input Volts Output Volts kVA Amps Connection Diagram
200 220 18.3 83.3 1 - view »
208 229 19.1 83.3 1 - view »
220 242 20.2 83.3 1 - view »
230 276 11.5 41.7 2 - view »
240 264 22 83.3 1 - view »
380 418 17.4 41.7 4 - view »
416 458 19.1 41.7 4 - view »
430 473 19.7 41.7 4 - view »
435 457 38.1 83.3 3 - view »
436 480 20 41.7 4 - view »
440 462 38.5 83.3 3 - view »
440 484 20.2 41.7 4 - view »
450 473 39.4 83.3 3 - view »
456 479 39.9 83.3 3 - view »
460 483 40.3 83.3 3 - view »
480 504 42 83.3 3 - view »
Buck Voltage (Reduce) - SINGLE PHASE
Input Volts Output Volts kVA Amps Connection Diagram
220 200 18.3 91.7 1 - view »
229 208 19.1 91.7 1 - view »
242 220 20.2 91.7 1 - view »
276 230 11.5 50 2 - view »
264 240 22 91.7 1 - view »
418 380 17.4 45.8 4 - view »
458 416 19.1 45.8 4 - view »
473 430 19.7 45.8 4 - view »
457 435 38.1 87.5 3 - view »
480 436 20 45.8 4 - view »
462 440 38.5 87.5 3 - view »
484 440 20.2 45.8 4 - view »
473 450 39.4 87.5 3 - view »
479 456 39.9 87.5 3 - view »
483 460 40.3 87.5 3 - view »
504 480 42 87.5 3 - view »


Boost Voltage (Increase) - THREE PHASE
Input Volts Output Volts kVA Amps QTY rqd Connection Diagram
173 208 15 41.7 2 5 - view »
200 240 17.3 41.7 2 5 - view »
208 250 18 41.7 2 5 - view »
362 380 57.5 83.3 2 6 - view »
380 418 30.2 41.7 2 7 - view »
400 440 31.8 41.7 2 7 - view »
419 440 66.5 83.3 2 8 - view »
436 480 34.6 41.7 2 7 - view »
457 480 72.6 83.8 2 8 - view »
480 528 38.1 41.7 2 7 - view »
480 504 72.8 83.3 2 8 - view »
346Y200 416Y240 30 41.7 3 9 - view »
379Y219 456Y263 32.9 41.7 3 9 - view »
400Y231 480Y277 34.6 41.7 3 9 - view »
416Y240 499Y288 36 41.7 3 9 - view »
Buck Voltage (Reduce) - THREE PHASE
Input Volts Output Volts kVA Amps QTY rqd Connection Diagram
208 173 15 50 2 5 - view »
240 200 17.3 50 2 5 - view »
250 208 18 50 2 5 - view »
380 362 57.5 91.7 2 6 - view »
418 380 30.2 45.8 2 7 - view »
440 400 31.8 45.8 2 7 - view »
440 419 66.5 91.7 2 8 - view »
480 436 34.6 45.8 2 7 - view »
480 457 72.6 91.7 2 8 - view »
528 480 38.1 45.8 2 7 - view »
504 480 72.8 87.5 2 8 - view »
416Y240 346Y200 30 50 3 9 - view »
456Y263 379Y219 32.9 50 3 9 - view »
480Y277 400Y231 34.6 50 3 9 - view »
499Y288 416Y240 36 50 3 9 - view »
NOTE: Y configured units must have Y supply for proper operation.



Shipping information


Shipping type Days Price
Ground 1 - 7 $44.12




Product information


Model:
TEMCo product ID
Brand Federal Pacific
Specifications:
Transformer subcategory Buck Boost
Electrical Specifications:
Phase Single
Frequency (Hz) 60
kVA 2
K rating 1
Primary configuration Two Winding
Secondary configuration Two Winding
Reverse connectable Yes
Winding material Copper
Electrostatically shielded No
Connection type Wire Leads
Mechanical Specifications:
Temperature rise (deg C) 115
Insulation system (deg C) 180
Enclosure rating NEMA 3R
Enclosure material Steel
Construction style Enclosed - Encapsulated Core & Coil
Mounting type Wall
Cooling Air/Dry
Other Information:
UL listed Yes
CSA approved Yes
Agency approvals ANSI C57.12, NEMA ST-20, TP1, EPACT 2005 (TP-1 & TSL-2)
Warranty 12 Years
Input voltage Output voltage
240x480 24/48
Weight & Dimensions:
Weight 50.00 lbs. (22.68 kg)
LxWxH 7.75 x 6.25 x 13.25 in.
(19.69 x 15.88 x 33.66 cm)
Shipping weight 21.00 lbs. (9.52 kg)